Oxygen: galvanic cell type
Hydrogen sulfide, carbon monoxide: potentiostatic electrolysis type
Oxygen: 0~25.0 vol%, (25.1~50 vol%)
Hydrogen sulfide: 0~30.0ppm, (30.1~150ppm)
Carbon monoxide: 0~150ppm, (151~300ppm)
Oxygen: 1st stage alarm 19.5 vol%, 2nd stage alarm 18.0 vol%
Hydrogen sulfide: 1st stage alarm 10ppm, 2nd stage alarm 15ppm
Carbon monoxide: 1st stage alarm 50ppm, 2nd stage alarm 100ppm
Combustible gas (methane or isobutane) with 8m tube: within 40 sec
Oxygen with 1m tube: within 20 sec
Hydrogen sulfide, carbon monoxide with 1m tube: within 30 sec
2) Leather case specification: 8m gas tube, sampling float, holster, storage case
3) Aluminum case specification: 8m gas tube, sampling float, external alarm (with 8m cable), AC adapter, aluminum case
4) Aluminum case specification: reel-type 8m gas tube, sampling float, reel-type external alarm (with 8m cable), AC adapter, aluminum case
※The aluminum case is a non-explosion-proof specification and is not NK certified
※For other optional accessories, please contact our company
|Measures oxygen, combustible gas, hydrogen sulfide, and carbon monoxide simultaneously and displays them together on the screen
|Sensors can be replaced directly, reducing maintenance time and cost
|Alerts are signaled through a large, conspicuous buzzer and indicator lights
|Equipped with a data logging function that records the detection date, time, gas concentration, and temperature every 30 seconds, for up to 150 hours
| With the data logging kit (optional), captured data can be easily managed on a computer|Available in three configurations to suit your needs: 1 m gas tube type, 8 m gas tube type, and aluminum case
|Intrinsically safe explosion-proof construction (Ex ib d IIB T3) *The combustible gas sensor uses pressure-resistant explosion-proof construction